Handheld Digital LCR Meter

二级分类:

ET43 Series Digital LCR Meter



 
Product Description
ET43 series handheld bridge is combined with 2.8 inch TFT display, flexible and convenient key operation and USB full speed communication , large capacity lithium battery can guarantee the long time work. Not only has comprehensive measurement parameters, but also can carry out deviation measurement and selection, output frequency can be adjusted continuously; in the performance, the basic accuracy of 0.2%.

(一)Features


 
  • Ø The measurement frequency reach to 100kHz, the 1Hz stepping can be adjusted continuously.
  • Ø DC resistance, electrolytic capacitance measurement
  • Ø Internal bias voltage output (10mV-500mV)
  • Ø Automatic identification of component measurement
  • Ø Support for screening and deviation measurement
  • Ø 2.8 inch TFT display, 4 half display
  • Ø USB communication interface
  • Ø Large capacity lithium battery power supply
  • Ø Support SCPI protocol
  • Ø Provide system settings, according to their own requirements configuration language, buzzer, screen brightness, etc.
  • Ø Basic measurement accuracy 0.2%, measurement speed can be adjusted
  • Ø Manual and automatic range
  • Ø Open circuit fault
 

 

General parameters

Model ET430B ET430 ET431 ET432 ET433
Measurement parameters Main parameter:L/C/R/Z
  Secondary parameter:X/D/Q/θ/ESR
Equivalent mode Series, parallel
Mode of range Manual, automatic
Measurement speed Fast(4 times/s), medium(2 times /s), slow(1 times /s)
Configuration of the test terminal 3-terminal, 5-terminal
Correction function Short circuit, open circuit
Communication interface Mini-USB(virtual serial port)
Frequency of test signal  
100Hz, 120Hz, 1kHz, 10kH
100Hz, 120Hz, 1kHz, 10kHz, 40kHz, 100kHz 100Hz, 120Hz, 1kHz, 10kHz 100Hz, 120Hz, 1kHz, 10kHz, 40kHz, 100kHz 10Hz-100KHz adjustable, 1Hz stepping
Level of test signal 0.6Vrms 0.6Vrms, 0.3Vrms, 0.1Vrms 0.1Vrms-0.75Vrms adjustable, 1mVrms stepping
Output impedance 100Ω
Highest accuracy (see accuracy indicators for details) Resistance: 0.25%
Capacitance: 0.4%
0.2%
Electrolysis and capacitance mode No Yes
DCR mode No Yes
Internal bias No 0-500mV adjustable, 1mV stepping
Scope of measurement L:0-2000H
C:0-20mF
R:0-20MΩ
 
 
Correction function Open circuit correction 
Screening function The limit range can be set to 1%-50%, which is fixed at 1%,5%,10%,20%
Deviation measurement The percentage of deviation between the nominal value of the component and the setting and display
else  Adjust backlight brightness, Device USB, automatic shutdown time can be set
ACCESSORIES
STANDARD 1,Mini-USB data Wires;      2, power adapter;         3, short circuit chip;
 4,red&black rubber plug;        5,large capacity lithium battery
  Kelvin test clip
Optional Kelvin test clip SMD test clamp SMD testing clamp
 
 
 
 

previous:No record next:No record 返回列表