ET2710 Digital Resistance RTD TC Temperature Calibrator
ET2710 Digital Resistance RTD TC Temperature Calibrator
Features and Benefits
· It allows you to measure DC V, DC mV, resistance ,TC and RTD.
· Outputs resistance, simulation of TC and RTD.
· Automatic and manual cold end temperature compensation for TC.
· Manual stepping, automatic stepping, 0~100% phase step and ramp output.
· Super-strong protection:The waterproof grade is IP67. Automatic protection against the signal terminals connect to the 220V.
Summary of Source and Measure Functions
Function | Measure | Source |
DC V | 0~30V | Not available |
DC mV | 0~120mV | 0mV~100mV |
Resistance | 0~3200Ω | 0~3200Ω |
RTD | Pt100, Pt1000, Cu50, Cu100 | Pt100, Pt1000, Cu50, Cu100 |
TC | E,J,K,T,B,R,S,N | E,J,K,T,B,R,S,N |
Others | Stepping output, ramp, phase step output, user-defined range |
Specifications
Specifications are based on a one year calibration cycle and apply from +18°C to +28 °C unless stated otherwise. All specifications assume a 10 minute warmup period.
DC Voltage Measurement
Range | Maximum measurement range | Resolution |
Accuracy (% of reading+counts) |
|
ET2710 (0.05%) | ET2710 (0.02%) | |||
30V | 0V~31V | 0.001V | 0.05+2 | 0.02+2 |
100mV | -15mV~125mV | 0.01mV | 0.05+2 | 0.02+2 |
-10°C~18°C,+28°C~55°C temperature coefficient, ±0.005%FS/°C.Input resistance: >1MΩ. |
Range | Maximum measurement range | Resolution | Accuracy (Ω) | |||
ET2710 (0.05%) | ET2710 (0.02%) | |||||
2-wire, 3-wire | 4-wire |
2-wire, 3-wire |
4-wire | |||
400Ω | 0~440Ω | 0.01Ω | 0.25 | 0.15 | 0.15 | 0.10 |
3200Ω | 420Ω~3600Ω | 0.1Ω | 1.5 | 1.0 | 1.0 | 0.5 |
-10°C~18°C,+28°C~55°C temperature coefficient,±0.005%FS/°C. Exciting current during measurement: 400Ω:1.0mA±10%; 3200Ω:0.2mA±10%; Two-wire: Conductor resistance is excluded from errors. Three-wire: Matching test line should be used. The total resistance of conductor should not be larger than 25Ω. |
Graduation | Range | Resolution | Accuracy (Ω) | |
ET2710 (0.05%) | ET2710 (0.02%) | |||
J |
-200°C~0°C 0°C~1200°C |
0.1°C |
1.5°C 1.0°C |
1.0°C 0.7°C |
K |
-200°C~0°C 0°C~1370°C |
0.1°C |
1.8°C 1.2°C |
1.2°C 0.8°C |
T |
-200°C~0°C 0°C~400°C |
0.1°C |
1.8°C 1.2°C |
1.2°C 0.8°C |
E |
-200°C~0°C 0°C~950°C |
0.1°C |
1.5°C 1.0°C |
0.9°C 0.7°C |
R |
-20°C~0°C 0°C~500°C 500°C~1750°C |
1°C |
4°C 2.5°C 2°C |
2.5°C 1.8°C 1.4°C |
S |
-20°C~0°C 0°C~500°C 500°C~1750°C |
1°C |
4°C 2.5°C 2°C |
2.5°C 1.8°C 1.5°C |
B |
600°C~800°C 800°C~1000°C 1000°C~1800°C |
1°C |
3.5°C 2.5°C 2°C |
2.2°C 1.8°C 1.4°C |
N |
-200°C~0°C 0°C~1300°C |
0.1°C |
2.0°C 1.2°C |
1.5°C 0.9°C |
Errors of cold-junction compensation are not included in the table. Accuracy of cold-junction compensation: 1.5°C |
The calibrator accepts Pt100, Pt1000, Cu50 and Cu100, etc. The calibrator accepts RTD measurements inputs in two-, three-, or four-wire connections, with the three-wire connection the most common. A four-wire configuration provides the highest measurement precision, and two-wire provides the lowest measurement precision.
The other parameters
Temperature: - 10 ℃ ~ 55 ℃
Storage temperature: - 20 ℃ ~ 60 ℃
Weight: 350 grams
Dimensions: 185mm*93mm*47mm
Power supply: 6Pcs AAA battery ni-mh or AC ADAPTER
Communication channel: RS232
18P02 communication wires
Power adapter(18A52)
Probes(18A53)