ET2715 Current and Voltage Calibrator
浏览: 发布日期:2018-07-06


Summary:
ET2715 Current and Voltage Calibrator is a handheld calibration instrument with high precision, high resolution and high reliability that integrates output and measurement of V, mV, mA and Hz signals. The meter adopts large liquid crystal display with clear reading, and it also has adjustable back light source and automatic shutdown function. The meter can be supplied by dc or ac power supply, which is more convenient to use.

Features
Accuracy:0.02% or 0.05%
Perfect performance on waterproof protection: IP67 grade
In case of connecting 220V with automatic over voltage protection function.
With manual stepping, automatic stepping and 0 ~ 100% output of phase step and ramp function
LED with white backlight
Source of voltage, current and frequency.
Measure of voltage, current, loop current and frequency.
Manual stepping and automatic stepping and ramping.
 
Summary of Source and Measure Functions
Function Measure Source
DC V 0~30 V 0~10 V
DC mV 0~100 mV 0~100 mV
DC mA 0~24 mA 0~24 mA
Frequency 1.000Hz~99.999kHz 0.00Hz~20.000kHz
Others 24V power supply, Step, Ramp.
Specifications
Specifications are based on a one year calibration cycle and apply from +18°Cto +28 °C unless stated otherwise. All specifications assume a 10 minute warmup period.
1,DC Voltage Measurement
Range Maximum measurement range Resolution Accuracy
(% of reading + Counts)
ET2715(0.05%) ET2715(0.02%)
30V 0V~31V 0.001V 0.05+2 0.02+2
100mV -15mV~125mV 0.01mV 0.05+2 0.02+2
-10°C~18°C,+28°C~55°C temperature coefficient,±0.005%FS/°C.
Input resistance: >1MΩ.
2,DC mA Measurement
Range Maximum measurement range Resolution Accuracy
(% of reading + Counts)
ET2715(0.05%) ET2715(0.02%)
20mA 0~24mA 0.001mA 0.05+2 0.02+2
-10°C~18°C,+28°C~55°C temperature coefficient,±0.005%FS/°C.
Input resistance:<100Ω.
3,Frequency Measurement
Range Maximum measurement range Resolution Accuracy
(% of reading + Counts)
ET2715(0.05%) ET2715(0.02%)
100Hz 1~99.999Hz 0.001Hz 0.02+1 0.01+1
1000Hz 100~999.99Hz 0.01Hz
10kHz 1k~9.9999kHz 0.1Hz
100kHz 10k~99.999kHz 1Hz
Sensitivity: 10Hz~10kHz,Vp-p≥1V; the rest:Vp-p≥2V.
Wave form: 5 counting points should be added to errors of other wave forms. Commercial frequency can be measured directly.
 
 
 
 
 
 
 
 
 
Using environment temperature:-18℃~55℃
Store environment temperature:(-20 – 60)°C
Relative humidity :0~ 90RH No condensation
Weight:0.35Kg
Size:185mm×93mm×47mmm
Power supply: 6 R03-model rechargeable batteries or power adapter
communication mode:RS232
 
 
1,Standard Accessories
A set of  calibrator also includes the following items:
hard spot test leads (one set)
alligator clips (one set)
One 12V/1A power adaptor
 Users Manual
2,Optional Accessories
6 R03-model rechargeable batteries
1 Metal Box
18P02 communication wires
Power adapter(18A52)
Probes(18A53)
 

Copyright © 2017-2020 杭州中创电子有限公司     备案号:浙ICP备18021705号-4

技术支持:杭州中创